31
Disconnect the wiring connector.
Remove the valve by two screws of the valve
holder.
When reconnecting the connector
2
1
3
4
INLET VALVE
VALVE
(DRY) YL/BK - BK
VALVE
(PRE-WASH) GY/WH - BK
VALVE
(NORMAL-WASH)
WH/BK - BK
VALVE
(HOT)
BL/RD - BK
Remove the lower cover to arrow direction
after one screw is unscrewed.
COVER LOWER
Rotate the Cap(Remaining Hose) to arrow
direction.
Pull it out from hose.
First, prepare a bucket to put in the remained
water.
Cap(Remaining Hose)
Removing method of remained water