Electrical Installation Requirements - Model IWF025 (M-speed)
Only trained personnel should perform this
procedure. Use caution while servicing
machines with covers removed and power
applied.
W700
WARNING
Boiler Fed/Steam Heat Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Recommended
Circuit Breaker
(US-market)
AWG/mm
2
kW Standard
Heating Elements
Full Load
Amps
Recommended
Circuit Breaker
(US-market)
AWG/mm
2
US NON-US US NON-US
N 440-480 50/60 3 3+PE 3 10 10 14/2.5
3x3 kW
N/A N/A N/A
N/A
P 380-415 50/60 3 3+N+PE 7 15 16 14/2.5 21 30 32
10/6.0
Q 200-240 50/60 3 3+PE 7 15 16 14/2.5 30 40 40
8/10.0
X 200-240 50/60 1/3 2/3+PE 7 15 16 14/2.5 N/A N/A N/A
N/A
Alternative Electric Heat Options
N 440-480 50/60 3 3+PE
3x1.4 kW
N/A N/A N/A
N/A
P 380-415 50/60 3 3+N+PE 13 15 16
14/2.5
Q 200-240 50/60 3 3+PE 18 20 20
12/4.0
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A
N/A
N 440-480 50/60 3 3+PE
3x2 kW
N/A N/A N/A
N/A
P 380-415 50/60 3 3+N+PE 16
20 20
12/4.0
Q 200-240 50/60 3 3+PE
23
30 32
10/6.0
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A
N/A
N 440-480 50/60 3 3+PE
3x4 kW
20 30 25
10/6.0
P 380-415 50/60 3 3+N+PE 24
30 30
10/6.0
Q 200-240 50/60 3 3+PE N/A N/A N/A
N/A
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A
N/A
Table 11