GE 500A436P006 Clothes Dryer User Manual


 
Installation
[] RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA 6.10
118" NPT PIPE
NEWMETAL PLUG FOR
GAS
FLEXIBLEGAS INLET PRESSURE
LINECONNECTOR
ADAPTER
ELBOW
3/8" NPT
SHUT-OFF
PIPE SIZE
ITEMSNOTSUPPLIED AT LEAST 1/2"
Note: The connector and fittings are designed for use onty
on the original insta[tation and are not to be reused for
another appliance or at another location. Keep flare end of
adaptor free of ]rease, oi[ and thread sealant.
Caution: Use adapters as shown. Connector nuts must not
be connected directly to pipe threads.
APPLYPIPECOMPOUND
TOTHEADAPTERAND
DRYERGASINLET.
TIGHTEN THE FLEXIBLE
GASLINE USING TWO
ADJUSTABLEWRENCHES.
Instructions
APPLYPiPECOMPOUND
TOALLMALETHREADS.
TIGHTEN ALL CONNECTIONS
USINGTWO ADJUSTABLEWRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
3
LEAK TEST
[,_ WARNING - NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE.
Check alt connections for leaks with soapg solution or equivalent.
Apply soap solution. Leak test solution must not contain ammo-
nia which could cause damage to the brass fittings. If leaks are
found, close valve, retighten the joint, and repeat the soap test.