Installation instructions
3-wire connections plus separate grounding connector
For use where local codes do not permit grounding through the Neutral wire.
Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 23.
A separate 10AWG copper grounding wire is required.
1
Remove the terminal block cover plate.
2
Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet
near the terminal block. Do not tighten strain relief screw until wiring connections are complete.
Note: a strain relief must be used.
2
strain relief
screws
strain relief
clamp sections
Fig.27 Inserting the power cord
3
Remove center terminal block screw.
4
Remove appliance ground link by removing the ground connector screw (Green screw).
5
Connect a separate copper ground wire (green with yellow stripe) using the ground connector
screw (Green screw). Make sure a ring terminal is used when connecting the ground wire and that
the wire is firmly secured to an adequate grounding path.
3
4
7
6
5
7
Note: If the appliance is
moved back to a 3-wire
installation the ground
link must be refitted.
Remove link
Fig.28 Connecting the wires
6
Connect the neutral wire (center) of the power supply cord to the center terminal screw of the
terminal block. Tighten screw.
7
Connect the other wires to the upper and lower terminal block screws marked with the letter L.
Tighten screws.
8
Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure
cover with securing screw.
9
Tighten strain relief screws.
It is recommended that a qualified electrician
determine that the ground path is adequate
grounding wire
8
9
Fig.29 Refitting terminal
block and tightening screws