Page 17
Gas Piping
Check gas rating plate for type of gas to equip the dryer.
Check for altitude elevation of the dryer.
Check utility for proper installation of gas supply line and gas
pressure.
NATURAL GAS ONLY
Check the gas pressure inlet supply to dryer, 11” W.C. Pressure
maximum. Check the manifold pressure 3.5” W.C. Pressure (Natural
Gas).
LP GAS ONLY
11” W.C. Pressure
CAUTION
Low gas pressure and intermittent gas will cause gas ignition
problems. This will cause inadequate drying of the clothes
load.
IMPORTANT
The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 PSIG.
IMPORTANT
The dryer must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG.
GAS PIPING
INSTALLATION