Piping Recommendations
1. Trap each dryer individually. Always keep the trap clean and
in good working condition.
2. When dryer is on the end of a line of equipment, extend
header at least 4 feet beyond dryer. Install globe valve,
union, check valve and by-pass trap at end of line. If gravity
return to boiler, omit trap.
3. Insulate steam supply and return line for safety of
operator and safety while servicing dryer.
4. Keep dryer in good working condition. Repair or replace any
worn or defective parts.
1. Keep steam coils clean.
2. Check periodically and clean as often as required.
3. Remove lint and dirt accumulation from coil fins periodically
as dirty lint-laden coil fins decrease the efficiency of steam-
heated dryers.
PIPING
RECOMMENDATIONS
STEAM HEATING
UNITS