Cissell L36USD36G Clothes Dryer User Manual


 
Page 14
General Information & Grounding Instructions
The Cissell Dryer is so designed that when an operator opens the dryer door, the
basket and exhaust fan stops. You can expect fast drying from a Cissell Laundry
Dryer. Hot, dry air is properly and effectively moved through the basket and
exhausted through a lint trap to the atmosphere. The Cissell Dryer comes
equipped with an inclined, self-cleaning lint screen. In this system, lint
accumulates on the underside of the screen until a blanket approximately 1/4”
thick is formed. This blanket of lint will fall from the screen to the bottom of the
dryer cabinet and should be removed daily, or as required, to prevent an over
accumulation.
Permanent press, durable press and other modern day fabrics require the care
that your Cissell Laundry Dryers now provide.
At the end of the drying cycle, determined by the time and temperature; single
timer, a thermostatic control, automatically takes over and continues the rotation
of the fan and basket without heat, until the garment load reaches a safe, cool
temperature. This function is performed at the end of each drying cycle, and
because it’s controlled by the heat retained in the garments after the normal
drying period, its time can extend from one minute, up to five minutes. The
thermo-cool cycle is never too long or too short. Always the exact minimum
time required to reduce the temperature of the garment load to a safe and cool
handling temperature.
Dryers must be electrically grounded by a separate #14 or larger green wire
from the grounding terminal within the service connection box to a cold water
pipe, or through the fourth green wire properly grounded and connected to the
grounding terminal. In all cases, the grounding method must comply with
local electrical code requirements; or in the absence of local codes, with
the National Electrical Code as ANSI/NFPA 70 (Latest Edition).
See wiring diagram furnished with dryer. Your Cissell Dryer is completely
wired at the factory and it is only necessary for the electrician to connect the
power leads to the wire connectors within the service connection box on the rear
of the dryer. Do not change wiring without consulting factory as you may
void the factory warranty. DO NOT CONNECT THE DRYER TO ANY
VOLTAGE OR CURRENT OTHER THAN THAT SPECIFIED ON THE
DRYER RATING PLATE. (Wiring diagram is located on rear wall of dryer.)
GENERAL
INFORMATION
CISSELL
COOL-DOWN
ELECTRICAL
CONNECTIONS