American Dryer Corp. ML-79 Clothes Dryer User Manual


 
33
30 DAYS
Drain condensation filter bowls. This may vary depending on how often the equipment is used.
NOTE: Drain bowls with manual drain to keep accumulated liquids below element. Liquid will be
carried down stream if it reaches the element. This will damage the outlet humidity sensor.
Replace element when plugged.
90 DAYS
Remove lint from around basket (tumbler), drive motors, and surrounding areas. Remove lint from the gas
valve burner area with a dusting brush or vacuum clearer attachment.
Re-grease the two (2) 1-3/8” bearings that support the impellor/fan shaft. Use Shell Avania #3 grease or its
equivalent. Impellor (fan/blower) shaft bearings should be lubricated using a #3 grease or its equivalent.
Check to make sure that the set screws on the impellor/fan shaft bearings are tight.
Remove lint from around basket (tumbler), drive motors, and surrounding areas. Remove lint from gas valve
burner area with a dusting brush or vacuum cleaner attachment.
NOTE: To prevent damage, avoid cleaning and/or touching the Hot Surface Ignitor.
Remove lint accumulation from inside
6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust duct work system and from dryers
internal exhaust ducting.
NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN
CREATE A POTENTIAL FIRE HAZARD.
NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.
CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST
DUCT WORK. INSPECT and REMOVE ANY LINT ACCUMULATION WHICH CAN
CAUSE THE DAMPER TO BIND or STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of
the heat circuit safety switches or thermostats.
NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product Intended for the
cleaning of appliances is recommended.
Check ALL V-Belts for tightness and wear. Retighten, realign, or replace if required.
NOTE: V-Belts should be replaced in matched sets (pairs).