SECTION VIII
REVERSING TIMER SPIN/DWELL
ADJUSTMENTS
Dual timer models with "reversing option" have an electric reversing timer in the electric service box which is
located in the upper rear area of the dryer.
Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches
located on the electronic timer (as noted in the illustration below).
Timing Legend
Spin Time
Switch Position Number 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
dd
Dwell (Stop) Time 1 2 3 4 5
Switch Position Number 5 6 8 10 12
Time in Seconds*
* Values shown are +/- 1 second.