American Dryer Corp. ML-75HS Clothes Dryer User Manual


 
21
B. Electric Models Only
IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back side of the upper/top control door. In the case of 208 VAC or
230/240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
APPROX.
AMP DRAW
IMPORTANT: 3 phase figures shown are for a 3 wire service ONLY.
MLE-75 (Electric)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE
: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type
of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
KW 208/1ø (60 Hz) 240/1ø (50/60 Hz) 208/3ø (50/60 Hz) 240/3ø (50/60 Hz) 380/3ø (50 Hz) 416/3ø (50 Hz) 460/3ø (60 Hz)
20 105 90 --- --- 33 --- ---
24 --- --- 72 63 --- 36 33
30 --- --- 88 77 --- 45 41
33 --- --- --- --- 53 --- ---
36 --- --- 104 92 --- 53 48
40 --- --- --- --- --- 59 ---