The exclusive Fire Suppression System (F.S.S.) will extinguish fires that may start in the
drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and
interfaced with the microprocessor will trigger the F.S.S. water jet(s) to quickly extinguish
the flames. The water jet(s) remain on for 2 minutes and will automatically activate again if
a fire condition remains or reignites. While the water jet(s) are activated, the basket (tumbler)
will jog to move the water throughout the load. The microprocessor will display that the
system was activated and will continue to display until the dryer is attended to.
We have tried to make this manual as complete as possible and hope you will find it useful.
ADC reserves the right to make changes from time to time, without notice or obligation, in
prices, specifications, colors, and material, and to change or discontinue models.
SECTION X
FIRE SUPPRESSION SYSTEM (F.S.S.)
F.S.S. In Action