This dryer was manufactured with a burner manual reset hi-limit (gas models only) and basket (tumbler)/
lint chamber hi-limit thermostat, which is monitored by the Phase 6 computer. If either manual reset thermostat
is open prior to start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 6
computer will display an error code with an audio indication. If the basket (tumbler)/lint chamber hi-limit thermostat
is open, the display will read dRUM SAFETY FAIL. If the burner hi-limit thermostat is open, the display will
read bURNER SAFETY FAIL.
If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable
error code described above along with an audio indication. If the drum temperature is above 100º F (38º C), the
dryer will continue to run with no heat for 3 minutes or until the drum temperature has flattened below 100º F
(38º C). The clear/stop button on the Phase 7 keyboard (touch pad) must be pressed to clear the error
condition. The open manual reset hi-limit thermostat must be reset manually prior to the start of the next
cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
operation.
The location of the burner hi-limit is on the right side of the burner box and the basket (tumbler) hi-limit is
located in the lint chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.