24
2.
Technical Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ------------------1-inch F.P.T.
Inlet supply size ------------------1-inch F.P.T. (minimum)
Btu/hr input (per dryer) ---------415,000 (104,580 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryers gas valves internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valves internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas................... #2 = 0.2210 (5.6134 mm).
Liquid Propane Gas ...... #30 = 0.1285 (3.2639 mm).
TYPE OF GAS
NATURAL LIQUID PROPANE
Manifold Pressure* 3.5 inches W.C. 8.7 mb 10.5 inches W.C. 26.1 mb
In-Line Pressure 6.0 - 12.0 inches W.C.
14.92 - 29.9 mb 11.0 inches W.C. 27.4 mb
Shaded areas are stated in metric equivalents
TYPE OF GAS
Liquid
Propane
Conversion Kit
Part Number
ADC
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
IDG-120 415,000 104,580 3 #2 140839 3 #30 140819 883118
Shaded area is stated in metric equivalent