American Dryer Corp. D30 Clothes Dryer User Manual


 
8 JLA Limited 113239-5
SECTION II
SPECIFICATIONS
MAXIMUM CAPACITY (DRY WEIGHT) 25 lb
11.3 kg
TUMBLER DIAMETER 32-3/4”
83.2 cm
TUMBLER DEPTH 19”
48.3 cm
TUMBLER VOLUME 9.26 cu ft
262.21 L
TUMBLER/DRIVE MOTOR 1/2 hp*
0.373 kW
BLOWER/FAN MOTOR N / A
DOOR OPENING (DIAMETER) 21-1/2”
54.61 cm
DOOR SILL HEIGHT 31”
78.74 cm
WATER CONNECTION 3/4”-11.5 NH
(North America)
3/4” B.S.P.T.
(Outside North America)
DRYERS PER 20’/40’ CONTAINER 14 / 30
DRYERS PER 48’/53’ TRUCK 45 / 51
VOLTAGE AVAILABLE 100-480V 1,3ø 2,3,4w 50/60 Hz
APPROXIMATE NET WEIGHT 407 lb
184.6 kg
APPROXIMATE SHIPPING WEIGHT 446 lb
202.1 kg
AIRFLOW
60 Hz
460 cfm
13 cmm
50 Hz
383 cfm
10.85 cmm
HEAT INPUT 78,000 Btu/hr
19,656 kcal/hr
EXHAUST CONNECTION (DIAMETER) 8”
20.32 cm
COMPRESSED AIR CONNECTION N / A
COMPRESSED AIR VOLUME N / A
INLET PIPE CONNECTION 1/2” F.B.S.P.T.**
1/2” B.S.P.T.
(CE and Australia Only)
VOLTAGE AVAILABLE 208-460V 1,3ø 2,3,4w 50/60 Hz
APPROXIMATE NET WEIGHT 407 lb
184.6 kg
APPROXIMATE SHIPPING WEIGHT 446 lb
202.1 kg
AIRFLOW
60 Hz
460 cfm
13 cmm
50 Hz
383 cfm
10.85 cmm
EXHAUST CONNECTION (DIAMETER) 8”
20.32 cm
COMPRESSED AIR CONNECTION N / A
COMPRESSED AIR VOLUME N / A
OVEN SIZE
kW Btu/hr
kcal/hr
15 51,200
12,900
20 68,200
17,200
24 81,900
20,600
VOLTAGE AVAILABLE 100-480V 1,3ø 2,3,4w 50/60 Hz
APPROXIMATE NET WEIGHT 435 lb
197.3 kg
APPROXIMATE SHIPPING WEIGHT 474 lb
214.8 kg
AIRFLOW
60 Hz
460 cfm
13 cmm
50 Hz
383 cfm
10.85 cmm
STEAM CONSUMPTION 98.8 lb/hr
44.8 kg/hr
OPERATING STEAM PRESSURE 125 psi max
8.6 bar
EXHAUST CONNECTION (DIAMETER) 8”
20.32 cm
COMPRESSED AIR CONNECTION 1/8” F.N.P.T.
COMPRESSED AIR VOLUME 0.75 cfh
0.02 cmh
BOILER HORSEPOWER (NORMAL LOAD) 2.9 Bhp
SUPPLY CONNECTION 1” F.N.P.T.
RETURN CONNECTION 1” F.N.P.T.
Steam*** GasElectric
Shaded areas are stated in metric equivalents 2/13/04
* Reversing dryer available with 3-phase (3ø) 1/2 hp (0.373 kW) motors standard.
** Size of piping to dryer varies with installation conditions. Contact factory for assistance.
*** Specify air-operated or electromechanical steam damper system. Air-operated steam damper system must be provided with clean, dry, and
regulated 80 psi ± 10 psi (5.51 bar ± 0.68 bar) air supply.
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.