American Dryer Corp. D30 Clothes Dryer User Manual


 
113239-5 01422 822282 25
2. Technical Gas Data
a. Gas Specifications
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when the gas valve is on.
b. Gas Connections
Inlet connection ---------- 1/2” N.P.T.
Inlet supply size ---------- 1/2” Pipe (minimum)
Heat input (per dryer) --- 78,000 Btu/hr (19,656 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (19.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.2 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ....................#31 = 0.1200” (3.048 mm).
Liquid Propane Gas ........ #51 = 0.0670” (1.701 mm).
TYPE OF GAS
NATURAL LIQUID PROPANE
Manifold Pressure* 3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
In-Line Pressure 6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
27.4 mb
TYPE OF GAS
Liquid
Propane
Conversion Kit
Part Number
Btu/hr
Rating
kcal/hr
Rating
Natural Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
78,000
19,656
2 #31 140818 2 #51 140801 883297