American Dryer Corp. AD-200 Clothes Dryer User Manual


 
46
4. Blown 24 VAC control circuit fuse (fuse 3).
L. Microprocessor controller (computer) light emitting diode (L.E.D.) display reads “door” and
the microprocessor controller (computer) “Door” L.E.D. indicator is on...
1. Failed microprocessor controller (computer).
M. Microprocessor controller (computer) will not accept any keyboard (touch pad) entries, i.e., display
reads “FILL” and when keyboard (touch pad) entries are selected, the display continues to read
“FILL”...
1. Failed keyboard (touch pad) label assembly.
2. Failed microprocessor controller (computer).
N. Microprocessor controller (computer) will only accept certain keyboard (touch pad) entries...
1. Failed keyboard (touch pad) label assembly.
O. Microprocessor controller (computer) locks up and L.E.D. display reads erroneous message(s)
or only partial segments...
1. Transient power voltage (spikes)...disconnect power to dryer, wait one minute and reestablish power to
dryer. If problem is still evident ...
a. Failed microprocessor controller (computer).
b. Failed keyboard (touch pad) label assembly.
P. Dryer stops during a cycle, microprocessor controller (computer) buzzer (tone) sounds for
5-seconds, L.E.D. display reads “dSFL” for approximately 30-seconds and then returns to
“FILL”...
1. Loose connection somewhere between the microprocessor controller (computer) and the microprocessor
temperature sensor.
Q. Dryer stops during a cycle, microprocessor controller (computer) buzzer (tone) sounds only
for a few seconds, and then the microprocessor controller (computer) L.E.D. display returns
to“ FILL”...
1. Loose connection somewhere in the main power circuit to the microprocessor controller (computer).
R. Microprocessor controller (computer) L.E.D. display reads “SEFL”...
1. Microprocessor controller (computer) program (Program Location 2) is set incorrectly in the active
mode (“Sen”) where the dryer is not equipped with the optional rotation sensor...program must be set as
“nSen.”