8. Each dryer should be operated through one (1) complete cycle to assure that no further adjustments are
necessary and that
ALL components are functioning properly.
9. Microprocessor (computer) programs/selections...
a. Each microprocessor controller (computer) has been preprogrammed by the factory with the most
commonly used parameter selections. If computer program changes are required, refer to the Computer
Programming Manual which was shipped with the dryer.
K. SHUT DOWN INSTRUCTIONS
In the case where the dryer is to be shut down (taken out of service) for a period of time, the following must be
performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Disconnect the heat supply:
a. GAS MODELS ... discontinue the gas supply.
1) SHUT OFF external gas supply shut-off valve.
2) SHUT OFF internal gas supply shut-off valve located in the gas valve burner area.
b. STEAM MODELS ... discontinue steam supply.
1) SHUT OFF external (location furnished) shut-off valve.
2) SHUT OFF internal steam valves in the supply lines and the return lines.