American Dryer ML-200 Clothes Dryer User Manual


 
12
B. LOCATION REQUIREMENTS
The model ML-200 dryer requires 18-inches (45.72 cm) of space on each side of the dryer and 24-inches (60.96
cm) of space behind the unit for ease of maintenance. A minimum of 12-inches (30.48 cm) must be allowed
between the top of a gas dryer and the ceiling. A ceiling height of 120-inches (304.8 cm) is required for gas
dryers, and a ceiling height of 130-inches (330.2 cm) is required for a steam dryers. The dryer must be leveled
for proper operation. If shimming is required, put metal shims which are the same size as the base feet. The
dryer must be lagged to the floor.
Before installing the dryer, be sure the location conforms to local codes and ordinances.
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be
removed from the floor area that the dryer is to rest on.
IMPORTANT: "The dryer must be installed on non-combustible floors only."
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.