Programming
F232123
22
Cycle Options
Cycle options are programmable options that are in
effect for the duration of the selected wash cycle.
These options include:
Agitation action
Agitation speed (defaults to normal wash speed
regardless of setting)
Recirculation pump enabled or disabled (for
possible future application)
NOTE: Cycle option settings are unique to the cycle
for which they are programmed.
Use the Up or Down key to change the selected option.
Use the Start key to accept the selected option and
move on to the next one.
Agitation Action
The programmer may choose among four agitation
actions. Refer to Table 4.
Table 4
The selected agitation applies to the entire cycle. It is
possible to progam a different agitation action for each
of the 30 cycles. When “Ag 3” or “Ag 4” is in effect,
there is no agitation during the fill.
Agitation Speed
If “AgSn” or “AgSL” is selected, the machine will
default to normal wash speed regardless of the setting.
Recirculation Pump
This cycle option setting is intended to be used with
a possible future recirculation application. Selecting
either “nP
nP” or “PUnP” will have no bearing on
the wash cycle. However, the “nP
nP” setting is
recommended to prevent the corresponding output
on the output board from energizing.
Press the Start key after selecting this last cycle option
setting to begin editing the cycle segments.
Segment Programming
All cycle programs (“CY01” – “CY30”) can be
customized within a preset program structure. Each
cycle program consists of eleven program segments.
Refer to Table 5.
Table 5
Agitation Action Options
Display Description Percentage
Ag 1
27 seconds forward,
3 seconds pause,
27 seconds reverse,
3 seconds pause
90%
Ag 2
10 seconds forward,
20 seconds pause,
10 seconds reverse,
20 seconds pause
33%
Ag 3
3 seconds forward,
27 seconds pause,
3 seconds reverse,
27 seconds pause
10%
Ag 4
4 seconds forward,
56 seconds pause,
4 seconds reverse,
56 seconds pause
6.7%
Cycle Program Segments
Segment Display
PreWash PrE
Wash UASH
Fill 1 FIL1
Fill 2 FIL2
Fill 3 FIL3
Fill 4 FIL4
Fill 5 FIL5
Fill 6 FIL6
Fill 7 FIL7
Fill 8 FIL8
Fill 9 FIL9