Alliance Laundry Systems UW125VV Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
F232123
14
Table 2 lists the various displays and what they mean.
The operator should become familiar with these
computer displays.
Table 2
Display Indications
Display Meaning Display Meaning
FPC3, bP3
Program identification code (ROM)
These are examples only.
Lo Low water level
nEd Medium water level
Hold Wait...power has just been turned on. HI High water level
CY Cycle (followed by two-digit number) SUP1 Supply 1
tESt/CYC* Test cycle selected. SUP2 Supply 2
FAr Degrees Fahrenheit SUP3 Supply 3
CEL Degrees Celsius SUP4 Supply 4
HEAt Auxiliary heat enabled. SUP5 Supply 5 (SETUP option)
noHt Auxiliary heat disabled. SUP6 Supply 6 (supply 1 and 5)
tFIL Temperature-controlled fill enabled. SUP7 Supply 7 (supply 3 and 4)
ntFL Temperature-controlled fill disabled. SLo/For** Gentle wash speed, forward direction
CooL Automatic cool-down enabled. SLo/rEv** Gentle wash speed, reverse direction
noCL Automatic cool-down disabled. norn/For Normal wash speed, forward direction
Ag 1 Agitation 1 selected (90% agitation). norn/rEv Normal wash speed, reverse direction
Ag 2 Agitation 2 selected (33% agitation). drAI Drain enabled.
Ag 3 Agitation 3 selected (10% agitation). nodr Drain disabled.
Ag 4 Agitation 4 selected (6.7% agitation). dISt Distribution (load balancing before extract)
AgSn Agitation speed normal
SPIn/tInE*
Reads “SPIn” for one second, then “tI
nE” followed by
time for spin.
AgSL** Agitation speed low
PU
nP Pump output enabled (future use only). SPn1 Lowest of three spins
nPnP Pump output disabled (future use only). SPn2 Middle of three spins
PrE PreWash segment (1st of 11 segments) SPn3 Highest of three spins
UASH Wash segment (2nd of 11 segments) STOP Stop routine
FIL1 First fill (3rd of 11 segments) SdLY Spin coast delay
FIL2 Second fill (4th of 11 segments) donE Cycle and stop routine have ended.
FIL3 Third fill (5th of 11 segments) dFLt Drive fault detected.
FIL4 Fourth fill (6th of 11 segments) door Door not properly closed.
FIL5 Fifth fill (7th of 11 segments)
bAL/FAIL*†
Balancing routine failed during test cycle after
7 attempts to balance load.
FIL6 Sixth fill (8th of 11 segments)
FIL7 Seventh fill (9th of 11 segments)
FILL/STOP*
Programmed water level not reached after
30 minutes.
FIL8 Eighth fill (10th of 11 segments)
FIL9 Ninth fill (11th of 11 segments)
FULL
The computer detects low water level or higher when
none should be present.
CFIL Cold fill
bFIL Warm fill (both hot and cold)
rotA
Computer detects possible rotation of motor when there
should be none.
HFIL Hot fill
AFIL Auxiliary fill (SETUP option) tSFL Temperature sensor failure or temperature out of range.
SPC? Special test cycle function (if present, ignore) bAL? Special test cycle function (if present, ignore)
* Display indications separated by a slash represent a flashing display.
** For UW100VV and UW125VV models, the washer-extractor will operate at normal wash speed regardless of the speed settings.
† This occurs only in the TEST cycle and only if the AC inverter drive balance detection is used. If the AC inverter drive balance detection is not used, this
will NOT appear during the TEST cycle (note, there are two types of balance systems).