Alliance Laundry Systems T453I Clothes Dryer User Manual


 
Maintenance
29
M414462
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Every Three Months
Lint Removal
1. Clean the lint and any other foreign materials
from the air vents located on the motors. The
motors are air cooled and if the air vents become
clogged, the motor will overheat and the internal
thermal overload protector will cycle off.
2. Steam Models: Check the steam coils and
remove any lint buildup and/or replace air filter
in the coil fin area. This can be accomplished by
using compressed air or by fabricating a comb
that can be pulled across the fins of the coil.
3. Exhaust ducts should be periodically inspected to
ensure there has been no build-up of lint which
could obstruct the air flow.
4. Inspect the dryer area to make sure nothing is
obstructing the flow of combustion and
ventilation air.
5. Remove front panel and clean any lint buildup.
Belt Tension
Check belt tension and adjust if needed.
Every Six Months
Overall Check
Check the tumbler over thoroughly for loose nuts,
bolts and screws, and for loose gas, electrical and/or
steam connections.
GAS CONNECTIONS: (Unions, flared tube fittings)
Check for leakage that might be caused by vibration.
Use a non-corrosive leak detention fluid. DO NOT
USE A FLAME AT ANY TIME TO CHECK FOR
GAS LEAKS.
ELECTRICAL CONNECTIONS: Electrical service
and grounding connections should be examined for
proper tightness.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING