Alliance Laundry Systems T453I Clothes Dryer User Manual


 
Programming the Electronic OPL Control
21
M414462
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Automatic Dry and Condition Mode
When a temperature is selected, A0:00 will appear
in the display window. Press START to start the
tumbler. A*:** will appear in the display window.
The first * is the selected dryness level (dryness
levels less than zero will appear as -*), and the :**
is the elapsed time.
The degree of dryness can be altered. Use the MORE
pad, or the LESS pad, to increase or decrease dryness
level.
NOTE: Dryness level can only be altered prior to
the end of the first heat cycle.
Figure 12
When clothes reach selected dryness level, Cool Down
begins. AC:** will appear in the display window.
:** is the elapsed Cool Down time. When Cool
Down ends, tumbler automatically goes into wrinkle-
free and Lr (Load Ready) will appear in the display.
AC:** will be displayed when tumbler is in Auto
Cool Down. Typical cool down times for fabric
selections are preset as shown in Table 2. The cool
down time can only be altered before cycle is started.
To alter cool down time press the COOL DOWN pad
and then press the MORE or LESS pad (when cool
down time is altered, TC:** will be displayed). For 1
minute changes, press pad and release. For 5 minute
changes, press pad and hold. Cooling time can be from
1 to 39 minutes. To return to the Auto Cool Down,
press MORE or LESS pad until AC:** is displayed.
Figure 13
Use the CONDITION pad for items to be left damp for
ironing. Cn:00 will replace A0:00 in the display.
Automatic Cool Down ends when either a preset
temperature or a preset time is reached. Refer to
Table 2.
Table 2
T399I
HIGH
MEDIUM
MED LOW
LOW
NO HEAT
ON / SELECT
START
STOP/RESET
T399I
ON/SELECT PADS
T396I
AUTOMATIC COOL DOWN
TEMPERATURES AND TIMES
Fabric
Preset
Temperature
Preset Time
HIGH 100°F, 38°C5 Minutes
MEDIUM 90°F, 32°C8 Minutes
MED LOW 90°F, 32°C5 Minutes
LOW 90°F, 32°C5 Minutes
TEMP
MORE
CONDITION
LESS
+--
T396I
DRYNESS PADS