Special Cycle Mode
This allows the user to select the number of times the
tumbler will cycle from heat-on to heat-off. To enter
the Special Cycle Mode, press the SPECIAL CYCLE
pad after selecting a cycle. The display will read
SC:**. ** is the number of times the tumbler will
cycle from heat-on to heat-off. This number can be
changed by pressing the MORE or LESS pads. For
increments of 1, press pad and release. For increments
of 5, press pad and hold for 3 seconds. Range is from
1 99.
Press the START pad and the number shown after
SC: is the number of cycles selected, the number
will decrease as each cycle is completed. The default
cool down cycle for the Special Cycle Mode is
Automatic Cool Down.
NOTE: Since there is only 60 minutes of cycle time,
any cycles not completed within 60 minutes will be
skipped.
NOTE: Unlike the Time Dry mode and Automatic
mode, the regulating temperature in the Special
Cycle Mode has a range of 80°F (27°C) to 180°F
(82°C) or all heat cycles.
Special Time Mode
This mode is just like the Time Dry mode, except that
the regulating temperature for each heat cycle ranges
from 80°F (27°C) to 180°F (82°C). To enter the
Special Time mode, press the SPECIAL TIME pad
after selecting a cycle. The display will read St:**,
where ** is the drying time. This time can be
changed by pressing the MORE or LESS pads. For 1
minute changes, press the pad and release. For 5
minute changes, press the pad and hold. Maximum
drying time allowed is 60 minutes.
AC:** will be displayed when tumbler is in Auto
Cool Down. Typical cool down times for fabric
selections are preset. The cool down time can only be
altered before cycle is started. To alter cool down time
press the COOL DOWN pad and then press the
MORE or LESS pad (when cool down time is altered,
TC:** will be displayed). For 1 minute changes,
press pad and release. For 5 minute changes, press pad
and hold. Cooling time can be from 1 to 39 minutes.
To return to the Auto Cool Down, press MORE or
LESS pad until AC:** is displayed.
To start the cycle, press START. The total drying time
plus cool down time will display. During the cycle,
remaining time displays.
Security Lock-Out
The programming pads can be locked-out so
operators cannot change cycles on their own. When
lock-out is used, the operator can use only the factory-
set Automatic cycles and the one Custom cycle
allowed per Select pad. Before using lock-out, create
all desired Custom cycles.
To lock-out, hold SIGNAL pad and press MORE in
the idle mode.
To unlock, hold SIGNAL pad and press LESS in the
idle mode.
Show Mode
This mode will show all LEDs and light up entire
display while deactivating all pads. This mode allows
loading door to be opened and closed. To enter this
mode, the control must first be in the idle mode. Hold
the START pad and press the SAVE CUSTOM pad. To
exit Show Mode, hold the START pad and press the
SAVE CUSTOM pad.