Alliance Laundry Systems T453I Clothes Dryer User Manual


 
19
M414462
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Programming the Electronic OPL Control
Figure 9
Drying can be done automatically or by time dry.
When drying automatically, the tumbler stops drying
when laundry reaches the factory set or programmed
dryness level and starts cool down. When time drying,
the tumbler stops drying when programmed time ends
and starts cool down.
Both automatic and time dry have factory-set cycles,
but other cycles can also be created. Frequently used
cycles can be saved in the controls memory as Custom
cycles.
In all cycles, except No Heat, Wrinkle-Free begins
when Cool Down ends. During Wrinkle-Free, the
tumbler alternately stops for 2-1/2 minutes and then
runs without heat for 2-1/2 minutes until door is
opened or 60 minutes has elapsed.
The HIGH, MEDIUM, MED LOW, and LOW ON/
SELECT pads may be saved in one of four ways as a
custom heat cycle, refer to Table 1.
Table 1
T359I
NOTE: Not all tumblers will have reversing option.
STATUS
DRYING
COOL DOWN
DOOR OPEN
CUSTOM
HIGH
MEDIUM
MED LOW
LOW
NO HEAT
TEMP
DISPLAY
SIGNAL
F/ C
TEMP
PROGRAM
AUTO
SPECIAL
CYCLE
MORE
CONDITION
SPECIAL
TIME
COOL
DOWN
LESS
SAVE
CUSTOM
TIME
*
+--
*
PROG
AUTO
AUTO
ON / SELECT
START
STOP/RESET
REVERSING
T359I
One pre-programmed
NO HEAT cycle
Four pre-programmed
Automatic Dry heat
cycles
All of these cycles
may be used as
pre-programmed
from the factory . . .
They may be
modified for one
cycle without
being saved in
the memory . . .
They may be
modified and
saved in the
memory as one of
five CUSTOM
CYCLES.
OR OR
Custom Cycles
Automatic Dry Dries the load to one of eleven user-
selectable dryness levels for a given
fabric type, and then enters automatic
or user-variable cool down.
Time Dry Duplicates the functions of
electromechanical dual timer
controls, allowing the user to vary
temperature, drying time and cool
down time.
Special Cycle Allows the user to specify the
number of heating cycles and to
select from the full range of
temperatures for all heat cycles.
Special Time Similar to Time Dry, except that the
user may specify from 80°F (27°C)