Alliance Laundry Systems SF250PV Tilt Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Installation
F232102
22
Mechanical Installation Standard
Models
Mounting Bolt Installation for Standard
135 Pound Capacity and 250 Pound
Capacity Machines
High-strength 3/4-16 x 10 in. machinery anchors should
be embedded in 3500 psi reinforced concrete that is a
minimum of 6 in. thick. Refer to Figure 8 for the
mounting bolt layout for standard 135 pound capacity
models. Refer to Figure 9 for the mounting bolt layout
for standard 250 pound capacity models. (The front of
the washer-extractor is the bottom of the diagram.)
Refer to Figure 10 for detailed information regarding
the machinery anchor bolt that should be used.
Figure 8
Figure 9
Figure 10
CFS213N
135
56 in.
(1422 mm)
3 in.
(76 mm)
3 in.
(76 mm)
66.63 in.
(1691 mm)
1.25 in.TYP
(32 mm)
62 in.
(1575 mm)
61 in.
(1549 mm)
12.81 in.
(324 mm)
36 in.
(914 mm)
12.31 in.
(311 mm)
CFS214N
CFS215N
1 Locknut
2 Base Frame
3 3/4-16 x 10 in. Dia. Bolt
4 Grout
5 Anchor Bolt
250
66 in.
(1676 mm)
3 in.
(76 mm)
3 in.
(76 mm)
19.5 in.
(495 mm)
40.69 in.
(1034 mm)
20 in.
(508 mm)
77.5 in.
(1969 mm)
1.25 in. TYP
(32 mm)
72 in.
(1829 mm)
80 in.
(2037 mm)
2
1
3
4
MOUNTING BOLT DETAIL STANDARD MODELS
6 in.
(152 mm)
5
6 in.
(152 mm)
MIN