Alliance Laundry Systems PHM798N Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
49
F8138601
Table 5 (continued)
Voltage Designation Non-Electric Heat
Machines (Standard)
Electric Heat Machines
Model
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Breaker
*AWG
*mm
2
Full Load
Amps
Breaker
*AWG
*mm
2
35
X
(Through
7/31/09)
200 – 240 50/60 1/3 2/3 12/8 15/15 14/14 2.5/2.5 NOT AVAILABLE
X
(Starting
8/1/09)
200 – 240 50/60 1/3 2/3 15/8 20/15 12/14 4/2.5 NOT AVAILABLE
Q 200 – 240 50/60 3 3 8 15 14 2.5 42 50 6 16
O** 208 – 240 60 3 3 7 20 12 4 38 50 6 16
R
(Through
10/1/10)
380 – 480 50/60 3 3 6 15 14 2.5 23 30 10 6
N
(Starting
10/4/10)
440 – 480 50/60 3 3 6 15 14 2.5 23 30 10 6
P
(Starting
10/4/10)
380 – 415 50/60 3 3 6 15 14 2.5 23 30 10 6
60
X 200 – 240 50/60 1/3 2/3 15/9 20/15 12/14 4/2.5 NOT AVAILABLE
Q 200 – 240 50/60 3 3 9 15 14 2.5 71 80 3 25
O** 208 – 240 60 3 3 11 30 10 6 66 80 3 30
R
(Through
10/1/10)
380 – 480 50/60 3 3 7 15 14 2.5 37 40 8 10
N
(Starting
10/4/10)
440 – 480 50/60 3 3 7 15 14 2.5 37 40 8 10
P
(Starting
10/4/10)
380 – 415 50/60 3 3 7 15 14 2.5 37 40 8 10
80
Q
(Through
4/13/10)
200 – 240 50/60 3 3 9 15 14 2.5 105 110 1 50
Q
(Starting
4/14/10)
200 – 240 50/60 3 3 14 20 14 2.5 105 110 1 50
R
(Through
10/1/10)
380 – 480 50/60 3 3 10 15 14 2.5 39 40 8 10
N
(Starting
10/4/10)
440 – 480 50/60 3 3 10 15 14 2.5 39 40 8 10
P
(Starting
10/4/10)
380 – 415 50/60 3 3 10 15 14 2.5 39 40 8 10
Table 10 (continued)