504607
15
Electrical Requirements . . .
(Gas Dryers)
NOTE: The wiring diagram is located inside the
control hood.
Grounding Instructions
The dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The dryer is equipped
with a cord having an equipment-grounding conductor
and a 3-prong grounding plug. The three-prong
grounding plug on the power cord should be plugged
directly into a polarized three-slot effectively grounded
receptacle rated 110/120 Volts AC (alternating current)
15 Amps.
Do not modify the plug provided with the dryer—if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the qualified
electrician should correct the problem.
Do not operate other appliances on the same circuit
when this appliance is operating.
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses checked by a qualified electrician
to make sure your home has adequate
electrical power to operate the dryer.
W113
WARNING
D009IE0C
DO NOT
OVERLOAD
CIRCUITS
DO NOT
USE AN
ADAPTER
DO NOT
USE AN
EXTENSION
CORD
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
grounded.
W038
WARNING
This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged
directly into a properly grounded three-
prong receptacle. Do not cut or remove the
grounding prong from this plug.
W036
WARNING
D090IE1E
STANDARD 120 VOLT, 15 AMP, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
NEUTRAL
ROUND
GROUNDING
PRONG
GROUND
NEUTRAL
SIDE
“L1”
0
V.A.C.
115 ± 12
V.A.C.
115 ± 12
V.A.C.
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer to the electrical
power source.
W037
WARNING