Alliance Laundry Systems HC35 Washer User Manual


 
Installation
50
F232062
Electrical Installation
(Continued)
Cabinet Hardmount
Electrical Specifications
50-Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2-Speed Models
C 380-415 50 3 4 6 15 14 2.50 39 50 6 16.0
D 220-240 50 3 3 10 20 12 4.00 64 70 4 25.0
E 220-240 50 1 2 15 30 10 6.00 N/A
F 440-480 60 3 3 6 15 14 2.50 39 50 6 16.0
O 208-240 60 3 3 10 20 12 4.00 64 70 4 25.0
Y 208-240 60 1 2 15 30 10 6.00 10 20 12 4.00
3-Speed Models
A 208-240 60 3 4 13 30 10 6.00 64 70 4 25.0
C 380-415 50 3 4 7 20 12 4.00 39 50 6 16.0
D 220-240 50 3 3 13 30 10 6.00 62 70 4 25.0
F 440-480 60 3 3 7 20 12 4.00 39 50 6 16.0
O 208-240 60 3 3 13 30 10 6.00 64 70 4 25.0
Variable-Speed Models
O 208-240 60 3 3 10.9 15 14 2.50 66.5 70 4 2.50
Y 208-240 60 1 2 10.9 15 14 2.50 N/A
Note:
Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.