Alliance Laundry Systems HC35 Washer User Manual


 
Installation
48
F232062
Electrical Installation
(Continued)
Cabinet Hardmount
Electrical Specifications
25-Pound and 27-Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2-Speed Models
C380-41550344 15142.501515142.50
D220-24050336 15142.502425106.00
E 220-240 50 1 2 10 20 12 4.00 42 45 6 16.0
F440-48060334 15142.501620124.00
O208-24060337 15142.502525106.00
U
380 50344 15142.501515142.50
240 50336 15142.502425106.00
Y 208-240 60 1 2 10.5 20 12 4.00 N/A
Variable-Speed Models
(
27-pound capacit
y
models onl
y)
O 208-240 60 3 3 4.8 15 14 2.50 N/A
Y 208-240 60 1 2 4.8 15 14 2.50 N/A
Note:
Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.