© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
9001000
48
Electrical Specifications
Voltage Designation Standard Electric Heat
Model
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Breaker
AWG
/mm
2
Full Load
Amps
(Heating
Element
kW)
Circuit
Breaker
AWG
/mm
2
18 N 440-480 50/60 3 3+PE 6 15 14/2.5 20 25 10/6.0
P 380-415 50/60 3 3+N+PE Not available 17 20 12/4.0
Q 200-240 50/60 3 3+PE Not available 28 30 10/6.0
X 200-240 50/60 1/3 2/3+PE 10 15 14/2.5 Not available
25 N 440-480 50/60 3 3+PE 6 15 14/2.5 21 25 10/6.0
P 380-415 50/60 3 3+N+PE Not available 18 20 12/4.0
Q 200-240 50/60 3 3+PE Not available 29 30 10/6.0
X 200-240 50/60 1/3 2/3+PE 10 15 14/2.5 Not available
33
N 440-480 50/60 3 3+PE 6 15 14/2.5 32 40 8/10.0
P 380-415 50/60 3 3+N+PE 18 20 12/4.0 44 50 8/10.0
Q 200-240 50/60 3 3+PE 18 20 12/4.0 63 70 4/25.0
X 200-240 50/60 1/3 2/3+PE 18 20 12/4.0 Not available
35
N 440-480 50/60 3 3+PE 12 15 14/2.5 41 50 8/10.0
P 380-415 50/60 3 3+N+PE Not available 36 40 8/10.0
Q 200-240 50/60 3 3+PE Not available 58 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 12 15 14/2.5 Not available
40
N 440-480 50/60 3 3+PE 6 15 14/2.5 32 40 8/10.0
P 380-415 50/60 3 3+N+PE 18 20 12/4.0 44 50 8/10.0
Q 200-240 50/60 3 3+PE 18 20 12/4.0 63 70 4/25.0
X 200-240 50/60 1/3 2/3+PE 18 20 12/4.0 Not available
55
N 440-480 50/60 3 3+PE 12 15 14/2.5 41 50 8/10.0
P 380-415 50/60 3 3+N+PE Not available 36 40 8/10.0
Q 200-240 50/60 3 3+PE Not available 58 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 16 20 14/2.5 Not available
75
N 440-480 50/60 3 3+PE 12 15 14/2.5 41 50 8/10.0
P 380-415 50/60 3 3+N+PE 12 15 14/2.5 36 40 8/10.0
Q 200-240 50/60 3 3+PE 15 20 12/4.0 58 60 6/16.0
100
N 440-480 50/60 3 3+PE 17 20 12/4.0 62 70 4/25.0
P 380-415 50/60 3 3+N+PE 17 20 12/4.0 55 60 6/16.0
Q 200-240 50/60 3 3+PE 18 25 10/6.0 88 90 3/35.0
135
N 440-480 50/60 3 3+PE 17 25 10/6.0 62 70 4/25.0
P 380-415 50/60 3 3+N+PE 17 25 10/6.0 55 60 6/16.0
Q 200-240 50/60 3 3+PE 20 30 10/6.0 88 90 3/35.0
Table 6 (continued)