Installation
Permanent connection
In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the switch contacts and
of a type suitable for the required load in compliance with the current
electrical regulations.
The switch must not break the yellow and green earth cable at any
point.
This operation must be performed by a qualified electrician.
Important: The power supply cable must be easily accessible after
installing the machine.
Installation
The inlet hose is provided with a water stop device, which protects
against damage caused by water leaks in the hose which could develop
due to natural ageing of the hose. This fault is shown by a red sector in
the window “A”. Should this occur, turn the water tap off and refer to
your Service Centre to replace the hose.
Water drainage
The end of the drain hose can be positioned
in three ways:
Hooked over the edge of a sink using the
plastic hose guide supplied with the
machine. In this case, make sure the end
cannot come unhooked when the machine is
emptying.
This could be done by tying it to the tap with
a piece of string or attaching it to the wall.
In a sink drain pipe branch. This branch must be above the trap so that
the bend is at least 60 cm above the ground.
Directly into a
drain pipe at a
height of not less
than 60 cm and not
more than
90 cm.
The end of the drain hose must always be ventilated, i.e. the inside
diameter of the drain pipe must be larger than the outside diameter of
the drain hose.
The drain hose must not be kinked. Run it along the floor; only the part
near the drainage point must be raised.
Electrical connection
This machine is designed to operate on a 220-230 V, single-phase,
50 Hz supply.
Check that your domestic electrical installation can take the maximum
load required (2.2 kW), also taking into account any other appliances in
use.
Connect the machine to an earthed socket.
The manufacturer does not accept any responsibility for damage or