![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/3e/b3e18247-cd3a-4982-abb7-1c8ab7a98b7d/b3e18247-cd3a-4982-abb7-1c8ab7a98b7d-bg10.png)
15
route the cable such that it is located well away from any drive input power
or motor wiring. Also take care to route the cable away from any sharp
edges or positions where it may be pinched.
8. Take a moment to verify that the interface and all network cables have
sufficient clearance from drives, motors, or power-carrying electrical
wiring.
9. Configure the Profibus slave address via the DIP switches on the front of
the interface (refer to section 8).
10. Turn the power sources to all connected drives ON, and verify that the
drives function properly. If the drives do not appear to power up, or do not
function properly, immediately turn power OFF. Repeat steps 1 and 2 to
remove all power from the drives. Then, verify all connections. Contact
ICC or your local Toshiba representative for assistance if the problem
persists.