E-EQ-MX3MCPLUS-F-ARC MX3 Multi-Charger Plus User’s Guide
Analyze – Initial Charge
When a battery is in the charge/analyze pocket and the analyze dome switch has been pressed
within 15 seconds of inserting the battery, the analyze process is started. The first step of the
analysis process is to charge the battery, which takes approximately 3 hours.
CHARGE
1
ANALYZE
11.2V
Figure 9 LCD Screen, Analyze, Initial Charge
The LCD indicates:
The battery is charging (CHARGE).
This is the first charge cycle in the analyze process (1).
The battery is under analysis (ANALYZE).
The battery voltage under charge (11.2VDC). The voltage can vary from 9.0VDC to
12.7VDC.