![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/23/f2368de1-e100-4a32-91f0-fdaa256067e9/f2368de1-e100-4a32-91f0-fdaa256067e9-bgd4.png)
Adjusting the Machine
4-66
4
Customizing Settings
Wire Cleaning
If streaks appear on printed output, or random parts of the printed image are
missing, clean the corona assembly wires inside the main unit.
NOTE
•
It takes approximately 35 seconds to clean the wires.
•
Wire cleaning cannot be performed during printing.
•
The machine may clean the wires automatically if it detects that the wires are dirty.
1
Press (Additional Functions) ➞ [Adjustment/Cleaning] ➞
[Wire Cleaning].
2
Press [Start].
When cleaning is complete, try printing again.
Drum Cleaning
If you use the machine immediately after installation, or if the machine is not used
for a long period of time, such as during a holiday, there may be rare cases in which
the images printed become light or distorted. If the images printed are light or
distorted, clean the drum as necessary.
NOTE
•
It takes approximately 5 minutes to clean the drum.
•
Drum cleaning cannot be performed during printing.
1
Press (Additional Functions) ➞ [Adjustment/Cleaning] ➞
[Drum Cleaning].
2
Press [Start].
NOTE
If you do not want to perform cleaning, press [Cancel].