20
● Place the end of the emergency emptying
hose and that of the inlet hose in a bowl
placed on the floor and let water drain out.
● Screw the water inlet hose back on and
reposition the emergency emptying hose
after having put the cap on again.
● When you intend to start the machine up
again, make sure that the room temperature
is above 0°C.
Emergency emptying out
If the water is not discharged, proceed as
follows to empty out the machine:
● pull out the plug from the power socket;
● close the water tap;
● if necessary, wait until the water has cooled
down;
● open the pump door;
● place a bowl on the floor and place the end
of the emergency emptying hose into the
bowl. Remove its cap. The water should
drain by gravity into the bowl. When the bowl
is full, put the cap back on the hose. Empty
the bowl. Repeat the procedure until water
stops flowing out;
● clean the pump if necessary as previously
described;
● replace the emergency emptying hose in its
seat after having plugged it;
● screw the pump cover again and close the
door.
132962460.qxd 01/07/2008 10.35 Pagina 20