Electrical Shock Hazard
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in death,
fire or electrical shock.
WARNING
Electrical requirements
Minimum installation spacing for
recessed or closet installation, with
or without a pedestal
• The dimensions shown are for the
minimum spacing allowed.
• For closet installation, with a door,
minimum ventilation openings in the top
and bottom of the door are required.
Louvered doors with equivalent
ventilation openings are acceptable.
Closet installation — Dryer only
Minimum installation spacing for
cabinet installation
• The dimensions shown are for the
minimum spacing allowed.
• For cabinet installation, with a door,
minimum ventilation openings in the top
of the cabinet are required.
0 cm
(0")
0 cm
(0")
80 cm
(31-1/2")
35.6 cm
(14") max.
310 cm
2
(48 in
2
)
155 cm
2
(24 in
2
)
closet door
with vents
side view
closet or confined area
45.7 cm
(18") min.
7.6 cm
(3")
7.6 cm
(3")
0 cm
(0")
0 cm
(0")
0 cm
(0")
0 cm
(0")
80 cm
(31-1/2")
35.6 cm
(14") max.
recessed
area
side view
closet or confined area
45.7 cm
(18") min.
68.6 cm
(27")
0 cm
(0")
0 cm
(0")
0 cm
(0")
0 cm
(0")
68.6 cm
(27")
22.9 cm
(9")
80 cm
(31-1/2")
17.8 cm (7")
17.8 cm
(7")
Recessed or closet installation —
Dryer on pedestal
IMPORTANT: Observe all governing codes
and ordinances.
This dryer is supplied without an electric
cord and plug. It must be connected by a
competent electrician to a single-phase
electricity supply at the voltage shown on
the dataplate, using a suitable fixed wiring
installation in accordance with local and
national wiring regulations. A 3-wire
circular cord of minimum conductor size
2.5mm
2
cross-section area should be
used. A 30A supply fuse should be used,
and a switch with a minimum contact
separation of 3mm in both poles must be
incorporated into the fixed wiring for dryer
disconnection. This disconnection switch
should be accessible to the user after
installation. A cord clamp bush is provided
on the dryer, and should be tightened on
completion of wiring. The electrical mains
terminals are located behind the small rear
access panel (terminal block cover), and
connections should be made in
accordance with the terminal markings.
Remember to replace the terminal access
panel (terminal block cover).
If codes permit and an additional earth
bond wire is used, it is recommended that
a competent electrician determine that the
earth bond path is adequate.