Moyer Diebel MD18-2 Washer User Manual


 
INSTALLATION
6
Plumbing Connections
CAUTION:
Plumbing connections must comply with local sanitary and plumbing codes.
Water Connections
1. Connect the hot water supply (140
o
F/60
o
C Min) to the fill solenoid valve (located behind
the front panel). The fill solenoid valve is equipped with a flow control that will accept
water pressures from 20 psi to 70 psi.
2. Install a manual shut-off valve in the water supply line to accommodate servicing the
machine. The shut-off valve should be the same size or larger than the supply line.
3. The fill solenoid valve is equipped with a built-in strainer to protect from particles in the
water supply.
Drain Connections
1. Your Moyer Diebel glasswasher is supplied with a flexible 5/8" I.D. drain hose, which must
be connected to a 1-1/2" drain using a wye (Y) fitting. Additional drain hose may be
purchased from a Moyer Diebel parts distributor.
Detergent
1. Use a qualified detergent/chemical supplier for your detergent, rinse aid, and chemical
sanitizer needs.
2. Your machine is supplied with a chemical dispensing system that is internally wired and
ready for use. Insert the labeled
Chemical pickup tubes into the correct containers. The
pickup tubes have a strainer on the end to prevent crystallized chemical from clogging the
supply lines.
3. The cycle timer located in the main control cabinet is equipped with adjustable cams for the
chemical dispensing pump(s). The cams control the length of time that the pumps operate.
A qualified person should adjust the cam settings if necessary. Refer to the timer chart
diagram(s) at the end of the manual for timer cam locations and factory time settings.
NO
TE:
A nonchlorinated, nonfoaming commercial detergent is recommended for your glasswasher.
Rinse Aid
1.
Using a liquid rinse aid, insert the labeled
Rinse Aid pickup tube into the rinse aid container
.
Chemical Sanitizer
1.
Using a 5.25% or 8.4% sodium hypochlorite solution, insert the labeled
Chemical Sanitizer
pickup tube into the chemical sanitizer container.
2.
Contact your chemical supplier for adjustment of the chemical sanitizer
.
!