Gas supply
Installation material (hoses and
adapters) must be provided by the
installer.
Gas connection distances
This appliance must be installed with its
own shut off valve on the gas supply
line. The valve must be within 6 ft.
(1.8 m), and in the same room, of the
dryer.
An 1/8" NPT pressure tapping plug
must be installed immediately upstream
of the gas supply connection. This
allows the gas inlet pressure to be
checked.
a Flare union adapter
b 1/8" NPT pressure tapping plug
c Gas shut-off valve
For convenience (if allowed by code),
an AGA or CGA approved flexible
stainless steel gas hose (accordion
type) may be used between the gas
shut-off valve and the dryer. This will
allow the appliance to be moved from
the installation site for cleaning or
servicing. Make sure that nothing rubs
on the gas hose.
If there is any doubt concerning
installation, contact the Miele Technical
Service Department at the phone
number listed on the back of this
manual.