Miele PW 6065 Plus Washer User Manual


 
Electrical connection
,
This installation should be
performed by an experienced and
qualified technician, in accordance
with local codes and regulations.
The washer comes with a power cord
without a plug.
The machine is supplied as standard
for connection to a 208 V, 60 Hz, 20 A,
3-phase electrical supply.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
The machine must only be connected
to the voltage and frequency shown on
the data plate.
,
To convert the machine to
another electrical connection,
please read the converting manual
on the wiring diagram inside of the
washer. The conversion must be
performed by a Miele Service
Technician. Additionally the "Heating
level" setting must be adjusted.
,
Do not install devices to
automatically turn the washer off,
i.e. a clock timer.
Installation
54