The machine is equipped with an
interface socket so that data can be
transferred from Novotronic to a log
printer.
Please contact Miele Technical Service
to order printer cables.
The serial interface is RS 232
compatible.
Various printer types with
Epson-compatible fonts can be used
for printing.
Miele Technical Service maintains a list
of recommended printers.
Pin assignment 9-pin sub-D connector:
5 GND (ground)
3 TXD (send)
1-4-6 (bridge)
7-8 (CTS)
,
Printer initialization must only be
performed by Miele. Consult
Technical Service using the contact
information on that back of this
manual.
During program operation a protocol is
prepared. It can be printed using an
external printer.
The protocol contains the following
information:
–
date and device number
–
program start time and name
–
rinse blocks used
–
dosage system with dosage
temperature and target dosage
amount
–
target values for temperature and
holding times
– minimal temperature during the
holding time
– all errors (e.g., water supply defect)
– program end time
– warnings, e.g., salt required.
Data transfer (optional)
43