Miele G 7783 CD Washer User Manual


 
Programming special functions
The following special functions can be
programmed where appropriate:
1. Setting water inlet to level plus
time control instead of timed inlet
(60 secs).
If the inlet water pressure is lower than
2.5 bar, too little water will flow into the
wash cabinet. By selecting level plus
time control flow, more water will flow
into the wash cabinet, if there is an inlet
water pressure between 1 and 2.5 bar.
The setting is adjusted separately for
cold, hot and AD-water.
Switch off the machine.
1a. Cold water connection
Press T
1
and c at the same time,
hold them in and also swtich on the
machine with "I-0".
The current programme status "P..."
appears in the display.
Press F. "10" or "11" will appear in
the display.
"10" = Cold water connection time
control (60 secs)
"11" = Cold water connection level
plus time control
Press c to change from "10" to "11"
or vice versa.
Press h. "SP" appears.
Press h again. The change has
been recorded and the display field
clears.
1b. Hot water connection
Switch off the machine.
Press T
1
and c at the same time,
hold them in and also switch on the
machine with "I-0".
The current programme status "P..."
appears in the display.
Press E. "20" or "21" will appear in
the display.
"20" = Hot water connection time
control (60 secs).
"21" = Hot water connection level plus
time control
Press c to change from "20" to "21"
or vice versa.
Press h. "SP" appears.
Press h again. The change has
been recorded and the display field
clears.
1c. AD water connection
Switch off the machine.
Press T
1
and c at the same time,
hold them in and also switch on the
machine with "I-0". The current pro-
gramme status "P..." appears in the
display.
Press D. "30" or "31" will appear in
the display.
"30" = AD water inflow time control
(60 secs)
"31" = AD water inflow level plus time
control.
Press c to change from "30" to "31"
or vice versa.
Switching the machine on and off
27