Maytag MTW5807TQ Washer User Manual


 
5
Tools needed for securing the drain hose and leveling the washer:
Parts supplied:
Alternate Parts
Your installation may require additional parts. For ordering information, please refer to the
toll-free phone numbers on the front page of the Use and Care Guide.
Location Requirements
Selecting the proper location for your washer improves performance and minimizes noise and
possible washer “walk.”
Your washer can be installed in a basement, laundry room, closet, or recessed area. See
“Drain System.”
IMPORTANT: Do not install or store the washer where it will be exposed to the weather.
Proper installation is your responsibility.
You will need:
A water heater set to deliver 120°F (49°C) water to the washer.
A grounded electrical outlet located within 4 ft (1.2 m) of where the power cord is
attached to the back of the washer. See “Electrical Requirements.”
Hot and cold water faucets located within 3 ft (90 cm) of the hot and cold water fill
valves, and water pressure of 5-100 psi (34.5-690 kPa). Washers with triple dispensers
require 20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (2.5 cm) under entire washer. Installing the
washer on carpeting is not recommended.
A sturdy floor to support the washer weight (washer, water and load) of 315 lbs (143 kgs).
Do not store or operate your washer in temperatures at or below 32°F (0°C). Some water can
remain in the washer and can cause damage in low temperatures. See “Washer Care.”
Recessed area or closet installation
The dimensions shown are for the recommended spacing allowed (A and B), except the closet
door ventilation openings. The dimensions shown for the closet door ventilation openings (C)
are the minimum required.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances may be required for wall, door and floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the washer is recommended to reduce
noise transfer.
If a closet door is installed, the minimum air openings in the top and bottom of the door
are required (C). Louvered doors with air openings in the top and bottom are acceptable.
Companion appliance spacing should also be considered.
Adjustable or open end
wrench ⁹⁄₁₆" (14 mm)
Level
Wood block
Ruler or measuring tape
A. Beaded tie strap
B.Front leveling feet with nuts (2)
If You Have: You Will Need to Buy:
Laundry tub or standpipe
taller than 96" (2.4 m)
Sump pump system (if not already available)
1" (2.5 cm) diameter
standpipe
1¹⁄₄" (3.2 cm) diameter to 1" (2.5 cm) diameter standpipe
adapter, Part Number 280130
Overhead sewer Standard 20 gal. (76 L) 39" (99 cm) tall drain tub or utility
sink, sump pump and connectors (available from local
plumbing suppliers)
Floor drain Siphon break kit, Part Number 280129; additional drain
hose, Part Number 3357090
Water faucets beyond reach
of fill hoses
2 longer water fill hoses:
6 ft (1.8 m) Part Number 76314,
10 ft (3.0 m) Part Number 350008
Drain hose too short Kit Part Number 280131
Lint clogged drain Drain protector, Part Number 367031
A
B
A.Front view
B. Side view
C. Closet door with vents
A
B
C
19"
(48.3 cm)
0"
(0 cm)
0"
(0 cm)
27"
(68.6 cm)
1"
(2.5 cm)
25
¹⁄₂"
(64.8 cm)
4"
(10.2 cm)
14" max.
(35.6 cm)
3"
(7.6 cm)
3"
(7.6 cm)
24 in.
(155 cm )
2
2
48 in.
(310 cm )
2
2