3. Make a complete operational check of
ALL the operating controls to insure that the timing is correct and
that the temperatures are set properly.
4. Make a complete operational check of
ALL safety-related circuits (i.e., door switches, hi-limit thermostats,
sail switches, basket (tumbler) safety thermostats, etc.).
NOTE: The sail switch can be checked for proper operation by opening the control door while
the dryer is running and the heating unit (burner) active (on). The heating unit(s) should
shut off within a few seconds. If not, make the necessary adjustments.
5. Each basket (tumbler) should be operated through one (1) complete cycle to assure that no further
adjustments are necessary and that
ALL components are functioning properly.
IMPORTANT: The dryer baskets (tumblers) are treated with a protective coating. This coating
can be removed by tumbling old clothes or material in the baskets (tumblers)
using a mild detergent to remove the protective coating.
6. Computer Programs / Selections...
Each microprocessor controller (computer) has been preprogrammed by the factory with the most
commonly used program (parameter) selections. If microprocessor controller (computer) program changes
are required, refer to the computer programming manual which was shipped with the dryer.
J. SHUT DOWN INSTRUCTIONS
In the case where the dryer is to be shut down (taken out of service) for a period of time, the following MUST
BE performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the gas supply (for GAS MODELS ONLY):
1) SHUT OFF
external gas supply shut-off valve (for both the top basket [tumbler] and the bottom
basket [tumbler] where the independent supply line for each basket [tumbler] is used).
2) SHUT OFF
internal gas supply shut-off valve located in the gas valve burner area (for both the
top basket [tumbler] and the bottom basket [tumbler]).