Maytag MLG32PDA Clothes Dryer User Manual


 
18
* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
NOTE: Contact factory for electrical information not listed.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
ELECTRIC SERVICE SPECIFICATIONS (per Tumbler)
A seperate circuit breaker must be provided for each tumbler/pocket.
NOTES:
Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP
DRAW
MINIMUM
WIRE SIZE*
CIRCUIT
BREAKER
120 2 9.0 12 15
Providing local codes permit, power to the dryer can be made by use of a flexible U.L. listed power cord/pigtail
(wire size must conform to the rating of the dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief must be installed where the wiring enters the dryer.