Drain System
Standpipe Drain System
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute.
The top of the standpipe must be at least 39" (99 cm) high and
no higher than 72" (183 cm) from the bottom of the washer.
Recessed Area and Closet Installation Instructions
This washer may be installed in a recessed area or closet.
The installation spacing shown is in inches and is the minimum
allowable. Additional spacing should be considered for ease of
installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air openings
in the top and bottom are required. Louvered doors with
equivalent air openings are acceptable.
Recessed front view Closet side view
Minimum Installation Clearances
closet
door
Front view
3" (7.6 cm)
3" (7.6 cm)
24"
2
(155 cm
2
)*
48"
2
(310 cm
2
)*
24"
2
(155 cm
2
)*
48"
2
(310 cm
2
)*
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
Product Dimensions
0"
(0 cm)
0"
(0 cm)
closet door
17"
(43.2 cm)
14"
(35.6 cm)
max.
4"
(10.2 cm)
min.
1" (2.5 cm)
min.
cold
hot
A
B
C
E
D
F
G
I
J
K
L
M
N
H
A. 43" (109 cm)
B. 38 " (97 cm)
C. 35" (89 cm)
D. 1 " (3.8 cm)
E. 27 " (70.5 cm)
F. 25 " (65 cm)
G. Water inlets
H. 7" (18 cm)
I. Power supply cord
J. Water level switch & shaft
K. Label
L. 27" (68.5 cm)
M. 5 " (13.3 cm)
N. 1" (2.5 cm)
O. Drain hose
P. 5" (12.7 cm)
³⁄₄
1
8
1
2
1
2
1
4
Additional spacing should be considered for the ease of
installation and servicing.
Additional clearances may be required for wall, door and floor
moldings.
Additional spacing of 1" (2.5 cm) on all sides of the washer is
recommended to reduce noise transfer.
Companion spacing should also be considered.