LG Electronics D2532W Clothes Dryer User Manual


 
15
Safety Instructions
Installation Instructions
Operating Instruction
Troubleshooting Tips
Customer Service
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra
length so dryer can be moved if needed.
Strip 3V2 in. (8.9 cm) of outer covering from end of
cable. Strip insulation back 1 in. (2.5 cm). If using
3-wire cable with ground wire, cut bare wire even
with outer covering. Shape ends of wires into a hook
shape.
When connecting to the terminal block, place the
hooked end of the wire under the screw of the
terminal block (hook facing right), squeeze hooked
end together and tighten screw.
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green) from
external ground connector screw. Connect
appliance ground wire and the neutral wire
(white or center wire) of power supply
cord/cable under center, silver colored terminal
block screw. Tighten screw.
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer
rear panel. Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the
external ground connector screw to an adequate
ground.
1. Loosen or remove center terminal block screw.
2. Place the hooked end of the neutral wire (white or
center wire) of power supply cable under the
center screw of terminal block (hook facing right).
Squeeze hooked end together. Tighten screw.
3. Place the hooked ends of the other power supply
cable wires under the outer terminal block screws
(hooks facing right). Squeeze hooked ends
together. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer
rear panel. Secure cover with hold-down screw.
1. External ground connector
2. Neutral grounding wire (green)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 cm) UL-listed strain relief
1. External ground connector
2. Neutral grounding wire (green)
3. Neutral wire (white or center wire)
4. Grounding path determined by a qualified electrician