LG Electronics D2532W Clothes Dryer User Manual


 
13
Safety Instructions
Installation Instructions
Operating Instruction
Troubleshooting Tips
Customer Service
Electrical Connection Options
If your home has: And you will be
connecting to
Go to Section
4-wire connection: Power supply cord
4-wire direct A fused
disconnect or circuit
breaker box*
4-wire connection:
Direct Wire
4-wire receptacle
(NEMAType14-30R)
A UL listed, 120/240
volt minimum, 30
amp, dryer power
supply cord*
4-wire connection:
Power supply cord
3-wire receptacle
(NEMAtype10-30R)
A UL listed, 120/240
volt minimum, 30
amp, dryer power
supply cord*
3-wire connection:
Power supply cord
3-wire direct A fused
disconnect or circuit
breaker box*
3-wire connection:
Direct Wire
lf local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire connection"
section.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green) from external
ground connector screw. Fasten it under center, silver
colored terminal block screw.
1. External ground connector - Dotted line shows
position of NEUTRAL ground wire before being
moved to center terminal block screw
2. Center silver-colored terminal block screw
3. Green wire of harness
1. External ground connector
2. Green or bare copper wire of power supply cord
3. 3/4 in. (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green)
6. Neutral wire (white)
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear
panel Secure cover with hold-down screw.
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3
wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length
so dryer can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable,
leaving bare ground wire at 5 in. (12.7 cm). Cut V/2 in.
(3.8 cm) from 3 remaining wires. Strip insulation back 1
in. (2.5 cm). Shape ends of wires into a hook shape.
3. Connect ground wire (green or bare) of power
supply cable to external ground conductor screw.
Tighten screw.
4. Connect neutral wire (white or center wire) of power
supply cord to the center, silver colored terminal
screw of the terminal block.
1. 4-wire receptacle (NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. 3/4 in. (1.9 cm) UL approved strain relief
7. Ring terminals
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire
connections.
4-wire connection: Direct wire
5"
(12.7cm)
1"
(2.5cm)
1
2
3 4 5 7
6
6
5
3
2
1
4
3
2
1