Residue inside the drum. Clean the drum inside.
High water hardness.
Set suitable water hardness
4)
.
Loading door
does not
close
Filters not locked in place.
Install fine filter and/or snap course filter
into place.
Err (Error) on
the LCD.
Attempt to change parameters after start
of the programme.
Turn the dryer off and on. Set requested
parameters.
No drum
light
Programme selector in Off position. Turn it to any programme.
Defective light bulb. Replace light bulb (see next section).
Abnormally
elapsing time
on LCD
Time to end is calculated on the basis of:
type, volume and dampness of laundry.
Automatic process; this is not a machine
fault.
Programme
inactive
Full water reservoir.
Empty water reservoir
3)
, press Start/
Pause button.
Drying cycle
to short
Small laundry volume./Too dry laundry
for selected programme.
Select time programme or higher drying
level (e.g. Extra dry ).
Drying cycle
to long
5)
Fluff filters clogged. Clean fluff filters.
To high loading volume. Respect max. loading volume.
Laundry insufficiently spun. Spun adequately the laundry.
Particularly high room temperature - no
machine fault.
Lower the room temperature if possible.
1) In case of error message on the LCD (e.g. E51): Switch the dryer off and on. Set programme. Press the Start/
Pause button. Does not work? - inform local service and quote the error code.
2) follow program recommendation - see Programme chart chapter
3) see Maintenance and cleaningchapter
4) see Machine settings chapter
5) Note: After around 5 hours the drying cycle ends automatically (see Drying cycle complete section).
Replacing the drum light
Only use a special bulb which is designed
specially for dryers. The special bulb can be
obtained from your local Service Force
Centre.
Important! When the appliance is
switched on, the interior lighting switches
itself off after 4 minutes when the door is
open.
Warning! Do not use standard
bulbs! These develop too much heat
and may damage the machine!
Warning! Before replacing the bulb,
disconnect the mains plug; with a
permanent connection: fully unscrew
or deactivate the fuse.
1. Unscrew the cover above the bulb (this
can be found directly behind the loading
aperture, at the top; refer to
“Description of machine” section.)
22