Unpacking/General Installation (All Dryers)
Upon arrival of the equipment, any damage in shipment
should be reported to the carrier immediately.
Upon locating permanent location of a unit, care should be
taken in movement and placement of equipment.
See outline clearance diagrams for correct dimensions.
Remove all packing material such as: tape, manuals, skid,
etc
Leveling: Use spirit level on top of dryer. Adjust leveling
bolts on dryer (see adjustable leveling bolts in maintenance
section).
Check voltage and amperes on rating plate before
installing the dryer.
The construction of the dryers permits installation side-by-
side to save space or to provide a wall arrangement.
Position dryer for the least amount of exhaust piping and
elbows, and allow free access to the rear of dryer for future
servicing of belts, pulleys and motors. Installation
clearance from all combustable material is 0" ceiling
clearance, 0" rear clearance, and 0" side clearance.
Before operating dryer, open basket door and remove
blocking between front panel and basket. Read the
instruction tags, owner’s manual, warnings, etc.
IMPORTANT
Opening the clothes loading door deactivates the
door switch to shut off the motors, fan, gas, steam,
or electric element. To restart the dryer, close
the door and press in the push to start button.
IMPORTANT
This dryer is designed for a capacity maximum
load. Overloading it will result in long drying
times and damp spots on some clothes.
IMPORTANT
Maximum operating efficiency is dependent upon
proper air cIrculation. The lint screen must be
kept cleaned daily to insure proper air circulation
throughout the dryer.
IMPORTANT
Provide adequate clearance for air opening into
the combustion chamber.