IPSO DR50 Clothes Dryer User Manual


 
Page 14
Gas Piping Installation
1. The installation must conform with local codes, or in
the absence of local codes with the National Fuel
Gas Code as, ANSI Z223.1 or the CAN/CGA-
B149, Installation Codes.
2. Check identification nameplate for type of gas for
dryer.
3. Check the altitude of dryer.
4. Check with utilities company for proper gas
pressure and gas supply line.
5. Natural gas only—check the gas pressure inlet
supply to dryer, 11” water column (27.4 mbar)
maximum. Manifold pressure—3.5” water column
(8.8 mbar) pressure .
6. L.P. gas only—manifold pressure—13” water
column (32.4 mbar) maximum.
CAUTION: Low gas pressure and intermittent
gas will cause gas ignition problems and
inadequate drying of laundry.
GAS PIPING
INSTALLATION